New Accelerometer v5 for high-fidelity modal analysis
The new Accelerometer v5 redefines structural monitoring, capturing from low-amplitude ambient excitation to seismic-level events, and keeping every waveform on board. Cleaner input, better modes for modal analysis.
Get your insight on how it enhances you project analysis

What changed
We made upgrades that redefine what a wireless structural accelerometer can do in the field.
4× wider range
Events that saturated the previous versions are well within spec for the v5. Blast, piling, seismic: the same device handles all of it without reconfiguring.
4× more sensitive
At ±128 mg, resolution drops to 3.9 µg. Micro-vibrations the previous versions couldn't resolve are now measurable. Essential for ambient vibration testing and modal analysis.
2× deeper buffer
More samples per acquisition means longer, more complete waveforms. At 80 Hz the v5 captures over 3 minutes of continuous data per event.
New on-board storage
Up to 60,000 events with waveform, 250,000 without. Data stays safe even in underground or remote sites with intermittent connectivity.
Improve your modes with better data
Your modal output is only as good as the data feeding it. The v5 improves that data in three ways, and each one shows up directly in the modes you compute for a client.
Catch the weakest signals
Operational modal analysis runs on ambient excitation, low-amplitude by nature. At its ±512 mg setting the v5 resolves it instead of letting the modes sink into the noise floor.
Register stronger events
A seismic event clips a sensor capped at ±2.048 g. Seven ranges up to ±8.192 g keep the full peak in the record, on the same device, with no reconfiguring.
Reduce packet loss
When the link drops on a remote structure, on-board storage for 60,000 events with waveform holds the data instead of losing it.
Synchronized waveforms to mode shapes
The Modal Analysis Tool in MyMove takes the synchronized data from your Accelerometer v5 network and extracts the structural response your engineers work with.
The v5 was built for this. Its resolution captures micro-vibrations missed by other sensors. With up to 16,384 samples per acquisition, the waveforms going into the tool are long enough to extract reliable results without truncating windows and approximations.
What comes out:
- Mode shapes — how your structure deforms at each natural frequency
- Natural frequencies — where the structure resonates under load
- Damping ratios — how quickly energy dissipates after excitation
All computed natively in myMove. No external software. No data export. Same platform, same dataset, same moment.
Everything that changed from the previous version
Version 5 | Previous version | |
Range & resolution | ±512 mg → ±8.192 g, 7 selectable settings on one device | Up to±2.048 g |
Buffer depth | 16,384 samples per acquisition (1,311pre-trigger), longer waveforms for the Modal Analysis Tool | 8,192 samples |
On-board memory | 60,000 events with waveform, 250,000 without. Data safe with no connectivity | None |
Battery life | 8 years on internal battery (acquisition every 6 h), up to 13 years with the optional Battery Pack | 4.5 years on internal battery (acquisition every 6 h) |
Multi-device sync | ≤500 µs | ≤500 µs |
Request a tailored quote for your monitoring needs
Get a customized quotation based on your project specifications — from sensor selection to platform configuration and deployment support.
Get your insight on how it enhances you project analysis